Allen-Bradley 1734-OB8S – 8-Channel Safety Sourcing Output Module

Model: 1734-OB8S

Series Pending
Model 1734-OB8S
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Allen-Bradley 1734 POINT I/O Series Technical Notes

The Allen-Bradley 1734 POINT I/O series, developed by Rockwell Automation, is a modular distributed I/O platform deployed across heavy industrial sectors including petrochemical refining, nuclear power generation, offshore oil & gas, and large-scale discrete manufacturing. Its compact DIN-rail-mounted architecture supports high-density I/O expansion with per-point wiring, making it the dominant distributed I/O standard in North American process control infrastructure. The 1734-OB8S is a safety-rated 8-channel sourcing digital output module within this series, certified for use in SIL 2 safety instrumented systems (SIS) and compliant with IEC 61508 and IEC 62061 functional safety standards.

The Evolution of 1734 POINT I/O Architecture

The 1734 POINT I/O platform was introduced in the late 1990s as a successor to fixed-block I/O architectures, addressing the need for granular, per-point I/O expansion in distributed control systems. Early revisions used a proprietary backplane bus operating at 500 kbps; subsequent generations migrated to a high-speed serial backplane capable of 12 Mbps throughput. The platform supports multiple communication adapter options — DeviceNet, EtherNet/IP, ControlNet, PROFIBUS DP, and FOUNDATION Fieldbus — enabling integration into both legacy DCS environments and modern IIoT-connected architectures.

Safety variants, including the 1734-OB8S, were introduced as functional safety requirements became codified under IEC 61508 Ed.2 and OSHA PSM regulations. These modules operate on the same physical backplane as standard 1734 I/O but require a dedicated safety adapter (1734-AENTR or 1734-AENT) and are programmed exclusively through Studio 5000 Logix Designer with the Safety Task configuration. The series remains in active production as of 2026, with Rockwell Automation providing long-term availability commitments through its Lifecycle Status program.

1734 POINT I/O Full Catalog & Functionalities (SKU List)

Safety Digital Output Modules

  • 1734-OB8S: 8-channel safety sourcing digital output, 24V DC, SIL 2, IEC 61508 certified
  • 1734-OB4ES: 4-channel safety sourcing output with diagnostics, 24V DC, SIL 2

Safety Digital Input Modules

  • 1734-IB8S: 8-channel safety sinking digital input, 24V DC, SIL 2
  • 1734-IE4S: 4-channel safety analog input, 4–20 mA / 0–10V, SIL 2

Standard Digital Output Modules

  • 1734-OB2EP: 2-channel protected sourcing output, 24V DC, 2A per channel
  • 1734-OB4E: 4-channel electronically protected sourcing output, 24V DC
  • 1734-OB8: 8-channel sourcing digital output, 24V DC, 0.5A per channel
  • 1734-OW4: 4-channel relay output, 240V AC / 24V DC, 2A per channel

Standard Digital Input Modules

  • 1734-IB8: 8-channel sinking digital input, 24V DC
  • 1734-IB8S: 8-channel sinking input, 24V DC, high-speed version
  • 1734-IA4: 4-channel AC input, 120V AC
  • 1734-IV8: 8-channel sinking/sourcing input, 24V DC, IEC Type 1/3

Analog I/O Modules

  • 1734-IE2C: 2-channel current input, 4–20 mA, 16-bit resolution
  • 1734-IE4C: 4-channel current input, 4–20 mA, 16-bit resolution
  • 1734-OE2C: 2-channel current output, 4–20 mA, 16-bit resolution
  • 1734-IE2V: 2-channel voltage input, 0–10V / ±10V, 16-bit resolution

Communication Adapters

  • 1734-AENTR: EtherNet/IP dual-port adapter, supports Device Level Ring (DLR), safety-capable
  • 1734-AENT: EtherNet/IP single-port adapter, standard and safety I/O
  • 1734-ADN: DeviceNet adapter, 500 kbps

Power Distribution & Base Units

  • 1734-EP24DC: 24V DC power distribution module, 4A
  • 1734-TOP: Terminal base, spring-clamp wiring, single-point
  • 1734-TOPS: Terminal base, screw-clamp wiring, single-point

Quality Control for the 1734 POINT I/O Range

The 1734 series presents specific test challenges due to its high-speed serial backplane bus and the diagnostic complexity of safety-rated modules. DriveKNMS applies the following test protocol to all 1734 units prior to shipment:

  • Backplane communication verification using a live 1734-AENTR adapter and Studio 5000 Logix Designer connection test
  • Channel-by-channel I/O functional test under rated load conditions (24V DC, rated current per channel)
  • For safety modules (1734-OB8S, 1734-IB8S, 1734-IE4S): safety function proof test per IEC 61511-1 Clause 16, including output de-energize response time measurement
  • Firmware revision identification and documentation against Rockwell Automation Product Compatibility and Download Center (PCDC) records
  • Visual inspection of backplane connector pins, terminal base locking mechanism, and module housing for mechanical integrity
  • Burn-in cycle: 48-hour powered operation at ambient temperature prior to final inspection

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top