Allen-Bradley Micro850 Controllers – 2080-LC50-24QWB

Model: 2080-LC50-24QWB

Model 2080-LC50-24QWB
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Allen-Bradley Micro850 Series Technical Notes

The Evolution of Micro850 Architecture

The Micro850 platform was introduced by Rockwell Automation as a successor to the MicroLogix 1100 and 1400 lines, addressing demand for embedded Ethernet connectivity and modular expansion without requiring a full CompactLogix chassis. Early Micro850 units (circa 2012–2015) shipped with firmware 1.x and supported a limited plug-in module set. Firmware 3.x and later revisions introduced EtherNet/IP adapter functionality, expanded function block library support under IEC 61131-3, and compatibility with the CCW (Connected Components Workbench) programming environment.

The series uses a non-rack-based architecture: plug-in modules insert directly into the controller body (up to 4 slots), while expansion I/O modules connect via a dedicated side-bus connector. This architecture creates compatibility constraints — plug-in modules from the 2080-MEMBAK-RTC or 2080-SERIALISOL families are not interchangeable with Micro820 plug-ins. Engineers migrating from MicroLogix 1400 must account for differences in instruction set coverage, particularly for PID and HSC (High-Speed Counter) configurations. As of 2024, the Micro850 series is in a mature/sustained phase; Rockwell Automation continues to ship hardware but has shifted primary development investment toward the Micro870 and CompactLogix 5380 platforms. Long-term maintenance support for Micro850 installations remains critical for facilities with 10–20 year operational horizons.

Micro850 Full Catalog & Functionalities (SKU List)

Controllers (Base Units)

  • 2080-LC50-24QWB: 24-pt DC in/out, onboard Ethernet, USB, 4 plug-in slots, 24VDC supply
  • 2080-LC50-24QBB: 24-pt DC in/transistor out, no Ethernet, 4 plug-in slots, 24VDC
  • 2080-LC50-24AWB: 24-pt AC in/relay out, onboard Ethernet, 4 plug-in slots, 120/240VAC
  • 2080-LC50-48QWB: 48-pt DC in/relay out, onboard Ethernet, 4 plug-in slots, 24VDC
  • 2080-LC50-48QBB: 48-pt DC in/transistor out, onboard Ethernet, 4 plug-in slots, 24VDC
  • 2080-LC50-48AWB: 48-pt AC in/relay out, onboard Ethernet, 4 plug-in slots, 120/240VAC

Plug-In Modules (2080-Series)

  • 2080-IQ4: 4-pt 24VDC digital input plug-in module
  • 2080-OB4: 4-pt 24VDC transistor digital output plug-in module
  • 2080-OW4I: 4-pt isolated relay output plug-in module
  • 2080-IF2: 2-ch analog input plug-in, 0–10V / 4–20mA selectable
  • 2080-OF2: 2-ch analog output plug-in, 0–10V / 4–20mA selectable
  • 2080-MEMBAK-RTC: Memory backup and real-time clock plug-in module
  • 2080-SERIALISOL: Isolated RS-232/RS-485 serial communications plug-in
  • 2080-IQ4OB4: 4-pt DI / 4-pt DO combo plug-in module, 24VDC

Expansion I/O Modules (2085-Series)

  • 2085-IQ16: 16-pt 24VDC digital input expansion module
  • 2085-OW16: 16-pt relay output expansion module
  • 2085-IF4: 4-ch analog input expansion, 0–10V / 4–20mA
  • 2085-OF4: 4-ch analog output expansion, 0–10V / 4–20mA
  • 2085-IQ32T: 32-pt 24VDC digital input expansion, terminal block

Quality Control for the Micro850 Range

Micro850 controllers and associated plug-in modules undergo a structured inspection protocol at DriveKNMS prior to shipment. Base controller units are powered on and connected via USB to CCW (Connected Components Workbench) to verify firmware version readability, I/O point continuity, and Ethernet port link negotiation. Plug-in modules are seated into a test controller chassis and verified for correct enumeration in the CCW I/O tree. Analog plug-ins (2080-IF2, 2080-OF2) are tested against calibrated signal sources to confirm channel accuracy within published tolerance bands (±0.5% full scale). Relay output modules are cycled under resistive load to verify contact integrity. Units exhibiting firmware corruption, backplane communication faults, or physical connector damage are quarantined and excluded from inventory. Each shipped unit is accompanied by a test record and, where available, the original Rockwell Automation factory label with date code.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top